WebAug 26, 2024 · Ball bearings failure analysis using vibrations is widely researched. Bearings are main part of rotary machines that work for years if they work in a proper … WebFailure Root Cause = One Word = Fluting Application : ID Fan in Cement Plant Electrical Manager accepted to look into the problem closely even it is a fan bearing failure ;-) 189 12 Comments
Motor bearing fluting IEEE Conference Publication IEEE Xplore
WebApr 1, 2007 · Consider the following: Most motor bearings are designed to last for 100,000 hr, yet motors controlled by VFDs can fail within one month (720 hr). 1. Of the VFD-controlled, 30- to 60-hp vane-axial-fan motors an HVAC contractor installed on a large building project, all failed within a year (two within six months). WebJan 1, 2024 · In a phenomenon called fluting, the operational frequency of the inverter causes concentrated pitting at regular intervals along the bearing race wall, forming washboard-like ridges that result in noise and vibration [Figure 5]. Figure 5: Taken from a failed motor, the “fluted” bearing race wall (left) resulted from VFD-induced bearing ... great jones realty llc
Preventing Drive Induced Electrical Damage to AC Motor Bearings
WebMar 26, 2024 · Joined Oct 10, 2012. 3,752 Posts. #4 · Mar 22, 2024. They just installed a new 5,000 hp motor on a compressor and put grounding brushed on the compressor shaft. They said there was a grounding issue and it was causing arcing on the bearings. There is no VFD on the motor and the compressor shaft is turning about 13,500 rpm. WebHigh static loads on a bearing, coupled with vibrations can also cause brinneling to occur. If the bearing is supporting more weight than it is rated for or if it is carrying heavy weight while stationary, brinneling may occur. … WebWe had a AC motor on VFD and it had signs of EDM from install, it lasted 2009 (New motor) - 2016 with extra greasing on demand. And yes it was a FAG Insulated Bearing 6316-M-J20AA-C3. PeakVue Trend with the reductions with the extra greasing. Acceleration Pk Trend. It was only pulled when the manager could hear it! floating rate payer significato